UHF RFID
Soliddigi UHF RFID frequency setting up
Reader Configuration:
By right-clicking the reader entry the configuration window may be opened by clicking on
Advanced Reader Settings:

Picture 1: Entering Advanced Reader Settings

Picture 2: Advanced Reader Configuration Window – Settings Tab
Inventory Delay: By changing the Inventory Delay [ms] the additional waiting time between two
consecutive read cycles can be modified. To confirm a new value press the Set button. Please
note that because HID system is used, the minimal time delay between two consecutive read
cycles is 50ms due to system constrains. The total time between two read cycles will be then
50ms plus the Inventory Delay.
Tag Mode: With this pull- down menu the air interface protocol may be changed. Options are:
· Gen 2
· Gen 2 + RSSI
· ISO 18000-6B
To apply changes press the Set button.
RFIDOutput level: The Output level slider changes the output power of the internal PA. The output
power level ranges from maximum and is using the internal step attenuator that can vary the
power in 19 steps.
Previous:UART Pin Header for UHF RFID reader module
Next:No Information
Next:No Information
Articles
Contact
SolidDigi Technoliges, Inc.
Add: Room 310, Building A of Nano Sensor Park, 200 Linghu Ave, Taihu International Science Technology Park, New District, WuXi, JiangSu, China
TEL: +86-510-85387391
FAX: +86-510-85387691
E-mail: sales@soliddigi.com
Soliddigi United States Office:
Add: 1067 S Hover St, Unit E-150, Longmont,CO, United States
ZIP: 80501
E-mail: sales@soliddigi.com
- SolidDigi Copyright 2010-2012
- Add:Building A of Nano Sensor Park, 200 Linghu Ave, New District, WuXi, JiangSu, China
- Tel: +86-510-85387391 Email:sales@soliddigi.com